MVHR Repair in London

When an MVHR unit stops working, goes noisy or starts leaking, it's rarely obvious why — and the ductwork is usually hidden in a ceiling void or loft. We diagnose properly first, tell you what's wrong and what it will cost, and only then repair.

Last reviewed: by the MVHR Expert engineering team

We repair all major brands and fault-find the whole system, not just the box: ducting, valves, controls, condensate and electrical supply.

Faults we diagnose and repair

  • Fans not running, stuck on boost or cutting out
  • Rattling, humming, whistling or vibrating units
  • Condensate leaks and blocked traps or drains
  • Poor or no airflow at valves
  • Failed or unresponsive controllers and sensors
  • Fault codes and filter-warning lights that won't reset
  • Bypass damper and summer bypass faults
  • Disconnected, crushed or leaking ductwork

Common symptoms we're called out for

  • Unit completely silent or display dead
  • Water dripping from the unit or ceiling below
  • Loud noise that was not there before
  • One room has no airflow at all
  • Fresh air feels cold in winter (bypass stuck open)
  • Unit constantly on boost or permanently on low

How it works

  1. Describe the fault. Tell us the symptoms and, if possible, the unit make and any fault code showing.
  2. Diagnose on site. We test power, fans, controls, bypass, condensate and airflow to find the real cause.
  3. Quote before work. You get a clear price for the repair before anything is touched.
  4. Repair & verify. We fix the fault and re-measure airflow so you know the system is performing again.

Why is my MVHR noisy?

Noise usually comes from one of four things: dirty or unbalanced fan impellers, worn fan bearings, loose mounting or duct connections transmitting vibration, or airflow forced through a restricted filter or valve. Whistling at valves often means the airflow is set too high for that terminal.

A deep hum or rattle that has appeared recently is typically a fan imbalance or a loose fixing. A grinding sound suggests bearing wear, and the fan or motor may need replacing.

Why is my MVHR leaking water?

MVHR units produce condensate as warm, humid extract air cools across the heat exchanger. This drains away through a trap and pipe. A dry trap, blocked drain, kinked pipe or unit that is not level will cause water to leak out of the unit and into the space below.

Don't ignore a small drip — it often means the drain is partially blocked and will get worse.

Repair or replace?

Most MVHR faults — fans, controls, filters, condensate and balancing — are repairable at a fraction of replacement cost. If a unit is very old, parts are obsolete or the heat exchanger is damaged, we will say so and discuss replacement, but only after a proper diagnosis.

MVHR Repair: common questions

How much does MVHR repair cost in London?

We charge a £140 call-out which covers attendance and full fault diagnosis. Any repair fee is quoted and agreed before work starts, so there are no surprises.

Why has my MVHR stopped working?

The most common causes are a tripped fused spur or power loss, a failed controller, seized or failed fans, severely blocked filters triggering a fault state, or a condensate or sensor fault. A diagnosis on site is needed to confirm.

Is it safe to switch my MVHR off if it's faulty?

Switching it off for a short time is safe, but you should not leave a sealed, airtight home without ventilation for long. Moisture and indoor pollutants build up quickly, and condensation and mould can follow within days.

Do you repair every MVHR brand?

Yes — Vent-Axia, Nuaire, Titon, Zehnder, Vaillant recoVAIR, Brink, EnviroVent, Itho Daalderop, Systemair, Airflow and others.

Need an MVHR engineer in London?

Tell us the make of your unit and what's wrong. We'll confirm price and availability the same day.